SEARCH THE KAMCO SITE

Useful Information

Material Safety Data Sheets

List of Boilers with Aluminium Heat Exchangers

HOUSEHOLDERS;
Does your central heating system need a power flush?

Click here to find a local power flushing engineer
CLICK HERE
to find a local power
flushing professional

Pump Owners
Click here to activate
your Warranty

NEW: MAY 2010
Kamco Newsletter

Sign-up for the Kamco e-Newsletter

Name
Email Address

 


Kamco Limited is ISO9001 registeredKamco is a founder member of the Domestic Water Treatment Association.  Click here for more information.
SYSTEM-HUSH

PRE-COMMISSION CLEANSER FOR NEW SYSTEMS

• REMOVES CORROSION AND BAKED-ON LIGHT SCALE DEPOSITS FROM HEAT EXCHANGERS

• WORKS DURING NORMAL SYSTEM OPERATION WITHOUT REMOVAL OF BOILER OR PIPING
• MAY BE LEFT IN THE SYSTEM

Some heating systems can be susceptible to noise problems as a result of baked-on corrosion and limescale deposits on boiler heat exchangers.

Whilst power flushing may cure this, on some systems it may be an ongoing problem. The addition of one litre of SYSTEM-HUSH, together with SYSTEMSAFE-DM, is recommended to cleanse the heat exchanger during normal system operation. SYSTEM-HUSH may be left in the system without draining.

SYSTEM-HUSH works at a near neutral pH, taking rust, corrosion and light scale deposits into solution, without formation of particulate matter to cause blockages and damage pumps. Boiler heat transfer surfaces are left clean, restoring efficiency, and boiler noises are eliminated.

SYSTEM-HUSH may be used with all metals commonly used in heating systems, including ferrous metals, brass, copper, aluminium and galvanised steel. It does not cause deterioration of metallic or non-metallic components when used as recommended, enabling it to be used on older systems which may be in too poor a condition for aggressive descaling chemicals.

The self-neutralising and passivating properties of SYSTEM-HUSH remove the need for time consuming flushing procedures after use, and metal surfaces are left clean and corrosion free.

APPLICATION & USAGE:

One litre of SYSTEM-HUSH is sufficient to treat a typical central heating system of 100 litres capacity (approx 10 radiators).

If the system water is very dirty and heavily discoloured (indicating the presence of sludge and large quantities of black iron oxide corrosion deposits throughout the heating system), first drain and flush the system with HYPER-FLUSH flushing treatment.

To ensure that all SYSTEM-HUSH enters the system, add to the feed and expansion tank after isolating water supply and draining off 15 litres (3 gallons) of water. Allow the system to refill. Alternatively, the SYSTEM-HUSH may be injected directly into a radiator using a SYSTEMSURE Injector.

The heating system should be operated normally while the SYSTEM-HUSH is working, which may take 2-3 weeks for full effect. SYSTEM-HUSH may be left in the heating system after the cleaning process. It is not necessary to drain and refill after treatment, although the operator may wish to do so if the system water in the feed and expansion tank is still heavily discoloured by corrosion residues in the radiator and pipes.

In either case, SYSTEMSAFE-DM scale and corrosion inhibitor should be added to the system after the operation to prevent further scaling or corrosion.

 

System-Hush

Packaging:

• carton of 12 x 1 litres

• carton of 4 x 5 litres

• 25 litre drum


Click here for useful power flushing information USER GUIDES

 

 

 

 

 

 

 

 

 

 

 

© Kamco Limited: Unit 9, Curo Park, Frogmore, St Albans, Herts, AL2 2DD, UK (click here for map) - tel: 01727 875020 - fax: 01727 875335 Privacy Policy Click here to email Kamco